# Physical interpretation Natural seepage is represented as one-way groundwater discharge at terrain elevations. This is separate from constructed drains with surveyed or assumed inverts. The same law applies across political borders; a border is not an input to the law. Hand-drawn groundwater-flooding polygons provide inspection context, not an on/off mask or calibration target. For terrain band j, outward flow is `Q_j = area * fraction_j / resistance_days * max(head - elevation_j, 0)`. The code in `src/chu_swatplus/natural_seepage.py` implements this equation; `native_formula_check.json` and `integration_witness/` contain executed native comparisons. Area is in square metres, elevation in metres and resistance in days, giving flow in cubic metres per day. Resistance represents an effective near-surface restriction, not a measured drain spacing or depth. The [USGS Drain Package description](https://water.usgs.gov/nrp/gwsoftware/ModelMuse/Help/drn_object_pane.html) supports one-way, head-dependent discharge and describes conductance scaling to represent progressively inundated subcell terrain. The explicit terrain-band sum used here is a regional approximation with a similar purpose; it is not claimed to reproduce the built-in cubic scaling formula. Neither description establishes a site-specific resistance value. The [official NPF documentation](https://modflow6.readthedocs.io/en/6.6.1/_mf6io/gwf-npf.html) defines convertible cells as having saturated thickness that changes with head, unlike cells forced to remain fully saturated. Allowing the lower layer to dewater tests that physical distinction without inventing a different aquifer geometry. It activates inherited drainable storage, whose value remains an assumption. It does not establish that every mapped layer represents a known geological unit. A below-bottom numerical head in a convertible cell is not a usable water-table depth. Its flow and storage behavior must be assessed separately. Conversely, head above mean cell ground does not mean drainage is absent: a finite conductance permits a positive head difference while water is discharging. Maps must distinguish these situations and show seasonal behavior, not only the final day of a run. Production selection requires the executed historical and combined-model evidence. A faster outlet must be checked for sensitivity toward the open seepage limit; choosing a value solely to remove orange cells would not be a physical justification. No new field observations are required to perform these numerical and accounting checks.